Free shipping on
orders over $550
*Some Restrictions Apply
1800 646 091
orders over $550
*Some Restrictions Apply
Portable Ventilation Fan
- Diameter 250 mm - Single Phase - 220V
SKU #D1143665
View All Portable Fans (Ventilation)
OR
Select BLUE dropdown(s) below.
= the combination is not available.
Selecting GREY line also resets the options.
Product Video
Feature Video
Open For Business & Shipping Daily During Covid-19
General Description
Portable Ventilation Fan - Diameter 250 mm - Single Phase - 220V
The vent fan has a ventilation diameter of 250 mm, is single phase, and the voltage is 220V. It has an air volume of 45 cubic meters/min, and its max RPM rating is 2800 RPMs.
Function
The portable ventilation fan is used along with flexible ventilation ducts to circulate fresh air or remove unwanted air, and it may also be used to maintain a suitable working temperature. Ducts connect to the ventilator through a strap system. It can be used apart from ducts for the same purposes. The steel housing protects the motor and other interior parts, ensuring safe operation.
Applications
The vent fan can safely be used for air supply and exhaust in deep working spaces where ceiling fans are non applicable, especially for cable maintenance, ship building, municipal underground engineering, and chemical or industrial factories. The ventilator can also be used for drying.
Download Spec sheet
SKU #D1143665
Technical Details
Certifications: | CE, ETL, SAA |
---|---|
Type: | Portable Exhaust Fan |
Diameter: | 250 mm |
Voltage: | 220 V |
Phases: | 1 |
Frequency: | 50 Hz |
Wattage: | 300 W |
Max RPM: | 2800 RPM |
Explosion Proof: | No |
Air Volume: | 45 m3/min |
Air Pressure: | 295 Pa |
Noise: | 66 dBA |
Brand: | Deelat Industrial |
Do you have a question about this product?
Receive $5 off your purchase simply for asking a question! Ask us anything! In fact, we use questions asked on our website about our products to further inform future customers, so we want you to leave a question. In addition, you will automatically be entered in our monthly $100 giveaway when you ask a question!
Click for details »
If you need an answer to your question immediately, please call our friendly CUSTOMER SUPPORT.
Receive $100 For contributing to our community
After you purchase, contribute to our community below by reviewing the high-quality products we sell. We are confident in our quality and for your contribution, you will be automatically entered into our current month\'s $100 giveaway!
Click for details »
If you have feedback for our CUSTOMER SERVICE department, please email directly or call us toll-free 1-888-785-2677 and ask for Jesse.
Can this product be used to remove smoke from a wood fire in a flu?
Hello Damien, thank you for your question. Yes you can certainly use our portable exhaust fan to extract smoke from a wood fire. As long as the exhaust fan is not in the fire directly or in an environment more than 80°C than you should have no problem.
Hi there how much ducting comes with the fan?
Hello Adrien, thank you for your question. Ducting is not included with any of our fans or ventilators. Ducting is sold separately, we offer all different types of ducting insulated, explosion proof, high heat, etc, If you would like to purchase ducting with your fan please give our customer support team a call and we will make sure to match this portable exhaust fan with the correct duct work.
This product was recommended to us to use under our house to move the air. We are having water drainage issues causing dampness and mildew/mold smells. Can we safely use it for this purpose under our house? And how long can it safely run without being turned off? Thanks!
Hello Greg, thank you for your question. This ventilator can be run safely for 1000 hours straight without being turned off. However, the environment you are specifying does not seem to be ideal. The ventilator can work in max temps of 104F and 90% humidity. You will need to make sure this environment will not reach these max parameters.
What is the proper size flex house to user with this fan. 300mm? Thanks!
Hello John, thank you for your question. Yes the correct size to use with this ventilator is 300MM. We sell many different types of ducts in the 300MM size. Please contact our customer support team to discuss all the options we have.
can I used it to suck air out of a room?
Hello Alan, thank you for your question. Yes you can use this ventilator to extract air out of a room. You would just need to make sure to look at the airflow arrow and make sure you install the ducting accordingly. To use this ventilaotr ans an extractor the ventilator must be placed in the room/area you would like to extract air from and have the ducting installed on the end that the airflow is being directed to and make sure the other end of the duct is wherever you would like the extracted air moved to.
What Diameter ducting should I buy to correct fit on the 12" Portable Exhaust fan?
Hello Joel, thank you for your question. The ideal sized flexible ducts to use with out 12" portable exhaust fan would be our 12" and 13" flexible ducts. The 12" would fit snugly to the rim of the exhaust fan were as the 13" will slide right over it with no issue but will need to be tightened to the rim of the exhaust fan with either the strap provided with the duct or with duct clamps (sold separately).
Is there a fan curve for this product of volume versus static pressure?
Is 25 m3/min enough or suitable for sucking oil paint solvent fumes out or should I be getting a higher air volume ventilator?
Thank you for your question Grace. These fans can be used for suction, however we will need more information to calculate exactly. Please call our customer support line with any questions-888-667-5776
Hi, I work in wood and bone.pendants in a small space and wonder if u have a portable extractor to suck the dust out as I’m working
Hello Bishop, thank you for your question. This portable ventilator is certainly capable of being used as an extractor, however, how efficiently it would remove dust is something we are not too sure about as that is not the intended use of the ventilator.
Can I use this for dust removal in a heavy duty dusty area? Really dusty.
Yes, you can use this portable ventilation fan for an extremely dusty area.
I need to connect a hose to the intake side of the blower. The flange looks larger. What diameter hose may I use?
what fan do you recommend to move hot air out of an attic?
Hello Vincent Thank you for your question. This ventilator is great but we dont believe its the best option for your purpose of cooling an attic. We actually offer fans specifically for attic cooling. Copy and Paste this link to your web browser Please check this page to see all the different options be have for attic fans!
What is the CFM for this fan?
Hello Richard, thank you for your question. This Air Blower Fan has a CFM rating of approximately 213 CFM. If this fan does not have the air volume you are looking for we do offer other air blower fans that have a higher CFM rating, Please contact our customer support team to go over your options.
I have a mask as well but need better ventilation without dust coming in. Will this fan extract resin fumes?
What is the return policy? Thank you.
Hi Do Yeon. Products can be returned within 30 days with receipt, and if you are not satisfied with any merchandise, please contact us.
Will these portable fans work with a voltage regulator?
Yes, the fan can be adjusted by a voltage regulator.
Can this fan be used to improve subfloor air circulation in an internally/externally solid brick home? We have some small, fixed fans at the back of the house, but would like something during the wet weather, which makes the house smell musty.
If there is sufficient room in your home to position the portable Deelat exhaust fan SKU#: D1143665 then yes, you can place it in main area of your home to extract the moist air. You will need to have an open window or something to exhaust the air via a duct connected to the fan. Place the fan in the room, with a duct attached, and a duct which leads to the exterior of the home.
Can this fan be mounted vertically? So this fan is 12" so it takes a 12" ducting? BTW can the ducting be cut relatively easy?
To mount this portable ventilation fan vertically, you can buy a U-shaped frame that can adjust its angle. The frame will cost $9 if you contact our factory. Yes, the 12" fan takes 12" ducting. We can produce a duct of custom length if you are having difficulties cutting it yourself.
Is this fan motor weatherproof?
The portable ventilation fan is IP54, which means that it is protected against dust and splashing. This makes the fan acceptable for common weather patterns as long as the wind or precipitation is not severe.
Does this particular fan allow for ducts simultaneously on both ends?
yes
How long is shipping?
Hi Rachael, thanks for your question. Shipping is roughly six weeks. If you need assistance with your purchase, please call our sales team at 1-888-667-5776 or email at sales@deelat.com!
Would you recommend that this fan be plugged in to a GFCI outlet?
Hello William, thank you for your question. We always recommend to use GFCI outlets when plugging in any find of electronic or power tool. However, a regular outlet would do just fine as well.
Hi. I'm contractor for renovations. I need a ventilation for présure négatif. What you think its good for me?
Hello Daniel, thank you for your question. We highly recommend you use a ventilator with a negative pressure duct if you are working with negative pressure. This ventilator should be good to use in your application but make sure to use negative pressure ducting. If you have any other questions or concerns please do not hesitate to contact us
Can I place the ventilator by the window without a duct to suck out oil painting solvent fumes?
Hello Grace, Thank you for your question. This fan can be used without ducting, however we do reccomend that ducting is used with the fan for better filteration of fumes.
What is its weight of this product?
Hello Vivek, thank you for your question. The weight of our portable exhaust fan is 7 KG, that is roughly 15.5 pounds. Please let us know if you have any other questions.
Can this be used to vent a bathroom in an older nonvented area to remove moisture
Hello Wanda, thank you for your question. Our portable exhaust fan can be used to ventilate any type room or area that does not contain any type of flammable gas. It can certainly be used to remove moisture or fumes from a restroom. You should also look at our ducting that goes with this ventilator so you can make sure the moisture is extracted completely out of the restroom.