Industrial Deelat Products
menu Mobile navigation

DEELAT - Official Blog

Tag Archives: HVAC

Condensate Pump Buyers’ Guide: Types and Applications

Condensate pumps are widely used in HVAC systems and commercial buildings to manage condensate (or moisture) produced by industrial refrigeration, soda machines, dehumidifiers, and air conditioning systems. In effect, the pump is responsible for pumping the excess condensate out of the system into a holding tank. Ultimately, the condensate in the holding tank is piped to a drain.

Typically, small-scale condensate pumps are electrically powered, and they may be constructed out of heavy-duty steel or cast-iron. Condensate pumps made of cast iron typically last longer, but they are much heavier and more difficult to install.

Condensate Pump
Condensate Pump

How to Select a Condensate Pump

When choosing a condensate pump, there are a number of questions to ask. First, you should determine local regulations on condensate disposal. In some locations, there are strict guidelines for disposal. The reason is that condensate is comprised of water created by steam, and as a result may be contaminated with dust, bacteria, or chemical traces from water treatment.

Plus, there are several considerations you should make about the actual pump, including:

  • Tank Capacity: Condensate pumps are equipped with tanks that hold processed condensate. It’s important to match the size of the tank to the volume of output. Sizes range from very small of 2-4 liters, up to 150 liters or more. In general, the size of the tank must be larger for larger-scale systems like an industrial HVAC or refrigeration system.
  • Water Flow Rate: As condensate is input, it must be pumped out, and this is the pump’s water flow rate. Smaller pumps tend to have limited flow rates, from about 20 to 40 liters per hour. Commercial condensate pumps, though, have flow rates of 150 liters per hour and above. A good general rule of thumb: Choose a pump that has a flow rate of at least double of the rate condensate will flow into the pump.
  • Voltage: You’ll need to first determine what voltage you can support with your existing electrical supply. In general, condensate pumps are available as 115 or 230 volts, with the 230V units providing additional pumping power. Additionally, there are some industrial-grade pumps that have voltage up to 460.

Buy condensate pumps on Deelat.com. We have some of the best prices of any industrial supplier online. Browse our selection of cast-iron condensate pumps, as well as our standard HVAC condensate pumps.

HVAC Inspection Equipment: Humidity Gauges, Infrared Thermometers and Wind Meters

There are many reasons to have your HVAC system inspected regularly. A properly functioning system can save on heating and cooling costs, to prevent the growth of mold and for safety. Unfortunately, for property managers, HVAC system problems aren’t often visible and require specialized precision measurement tools to determine.

A humidity sensor, for example, determines a building’s relative humidity, which can lead to more efficient identification of equipment malfunctions. And infrared thermometers make heating and cooling problems, like a poor seal or improperly fitted furnace, easier to detect. Building and home inspectors, facilities managers, HVAC inspectors and electricians all use these specialized devices, because they provide quick, accurate measurements.

Infrared Thermometers for HVAC Inspection

The best infrared thermometers are often called temperature guns, because you just point them at a source to find the temperature. That makes these measurement tools extremely versatile. Using infrared thermometers, building inspectors and facilities managers can gauge temperatures in hard-to-reach places, like behind a piece of hardware.

Infrared Thermometer
Infrared Thermometer

Infrared thermometers are also referred to as laser thermometers, because they often use laser technology to measure the infrared energy emitted by a source. From that, they can determine the temperature. Generally, IR thermometers are used to gauge the temperature of a home or building’s heating system, like a hot water heater or furnace, as well as electrical and plumbing equipment.

Another common application: Infrared thermometers can be used to improve a building or home’s energy efficiency. Cold air leaks around HVAC systems and other areas where heat can be lost are easier to determine with infrared thermometers.

Humidity Gauges for HVAC Inspection

Humidity sensors are another important tool for property inspectors. Essentially, these gauges measure the relative humidity of an environment, and they have a wide application, they’re used in meterology for instance.

Humidity and Temperature Meter
Humidity and Temperature Meter

In building inspection, humidity gauges can help detect a few issues. First, they can determine airflow issues in an HVAC system; low relative humidity, for instance, might mean that an HVAC system isn’t delivering enough air to a particular area. In addition, humidity sensors can determine when relative humidity is higher than normal. When it is, the risk of mold growth is greater, because mold thrives in moist environments. This can cause a variety of problems, from wood rot and corrosion to impaired worker health.

Airflow and Wind Meters for HVAC Inspection

Anemometer
Anemometer

Finally, wind meters are used to determine the airflow from a heating or cooling vent. When placed in front of a heating vent, for example, one of these handheld devices measures wind speed, and using this data, HVAC inspectors can determine the consistency of hot or cold air. Thus, if an air conditioner isn’t providing enough air, or the flow isn’t consistent, that problem is very easy to determine.

Find the best deals and lowest prices on your HVAC inspection equipment at Deelat.com. We carry a range of precision measurement tools, including IR thermometers, wind meters, humidity detectors and more.