Customer Support
Call us toll free!
1800 646 091
Indoor Floor and Driveway Heating Cables and Mats (De-Icing)
Subcategory Questions Show all 89 questions
How hot do the cables get to the touch?Giancarlo V on Oct 24, 2017
Best answer
Hello Giancarlo, thank you for your question. These De-icing cables have a heat output of approximately 65-75F. It is not hot enough to burn your hand but certainly hot enough to melt built up snow and ice. The cables will certainly keep your gutters clear.
Reply
Inaccurate
Deelat Industrial on Oct 24, 2017
Add answer
I have this question too (3)
Show all answers (1)
How does one attach Outdoor De-Icing Cable – 60 M – 110 V - PVC to Spanish Tile Roof?JOSEPH A. on Oct 28, 2017
Best answer
Hello Joseph, thank you for your question. Deelat.com offers installation clips that are sold separately. This clips are universal and will slide underneath shingles or clip onto the edge on a piece of tile whether it be Spanish tile or a different style tile. If you wish to order this product please contact our customer support team to arrange the order with the additional clips.
Reply
Inaccurate
Deelat Industrial on Oct 31, 2017
Add answer
I have this question too (3)
Show all answers (1)
Can the cable be in the ground 6 inches?joe c. on Oct 30, 2017
Best answer
Hello Joe, thank you for your question. These de-icing cables could be buried in the ground but 6 inches could potentially be too deep and the heat might not be able to penetrate the ground to warm the surface. We have other cables that are specifically intended to be buried under dirt, asphalt, concrete, etc. Please look at out Driveway Heating Cable section.
Reply
Inaccurate
Deelat Industrial on Oct 31, 2017
Add answer
I have this question too (2)
Show all answers (1)
Can the cable be installed inside the sump pump drainage pipe outside? I could make a T with PVC to ensure air can get in to drain and to have a place the "plug-in end" of the cable can come out.Yvon D. on Jan 08, 2018
Best answer
Hello Yvon, thank you for your question. Our outdoor de-icing cables are intended to be used on roof tops and inside gutters. That being said, we cannot recommend using these cables for something that it is not intended for. We only recommend to use these cables for their intended use.
Reply
Inaccurate
Deelat Industrial on Jan 11, 2018
Add answer
I have this question too (2)
Show all answers (1)
Will this heating cable be suitable for laying INSIDE a 4" diameter PVC pipe - to prevent ice build-up ?Dale W. on Sep 29, 2017
Best answer
Hello Dale, thank you for your question. We do not recommend to install these inside of the pipe but instead to wrap the outside of the pipe with the heating cable. We suggest to spiral the cable around the outside of the pipe and the spirals should be no more than 2-3 inches apart.
Reply
Inaccurate
Deelat Industrial on Oct 03, 2017
Add answer
I have this question too (1)
Show all answers (1)
What area can 10M cover in square feet? Brent F. on Oct 25, 2017
Best answer
Hello Brent, thank you for your question. This driveway heating cable is 32 ft long by 2 ft wide. With these dimensions we would have to say this will cover an area of 64 sq ft. We offer different lengths of these driveway heating cables that will cover more area. Please contact our customer support team if you have any other questions.
Reply
Inaccurate
Deelat Industrial on Oct 25, 2017
Add answer
I have this question too (1)
Show all answers (1)
Can I wrap the cable around a truck battery?marcel p. on Nov 17, 2017
Best answer
Hello Marcel, thank you for your question. In theory, our Automatic Thermostatically Controlled Heating Cables can be wrapped around pretty much anything that is not flammable. That being said you could certainly wrap the cable around the battery but wouldnt recommend doing so inside the engine bay while the truck is running.
Reply
Inaccurate
Deelat Industrial on Nov 29, 2017
Add answer
I have this question too (1)
Show all answers (1)
Can I use the cable on a rubber roof. It does have a slant to it ( it is not flat)Patricia B. on Jan 12, 2018
Best answer
Hello Patricia, thank you for your question. Yes you can certainly use our outdoor deicing cables on your runner roof, however, would need to purchase the clips that are specifically designed to attached these cables to any roof. We do offer these clips for sale separately. Please contact our customer support team if you need help placing the order for the deicing cable and clips
Reply
Inaccurate
Deelat Industrial on Jan 16, 2018
Add answer
I have this question too (1)
Show all answers (1)
How high and how low can the thermostat be set at?Gregory B. on Jan 29, 2018
Best answer
Hello Gregory, thank you for your question. The thermostat on our automatic thermostatically controlled heating cables cannot be adjusted or set. Our heating cables come with their thermostats set at a preset temperature range from factory and cannot be changed. The cable is set to turn on when temps reach below 55 F (13 C) and shut off when gets above that temperature.
Reply
Inaccurate
Deelat Industrial on Feb 05, 2018
Add answer
I have this question too (1)
Show all answers (1)
Hello, I see that you don't recommend that THE CABLE BE INSTALLED INSIDE THE SUMP PUMP DRAINAGE PVC PIPE OUTSIDE. Do you have a product that could be used for this application?Scott P. on Apr 19, 2018
Best answer
Hello Scott, thank you for your question. Unfortunately we do not offer anything that would be suitable to be in water. Installing our heating cables submerged entirely in water is a potential electrical hazard and not safe. The cables can get wet but should not be completely submerged.
Reply
Inaccurate
Deelat Industrial on Apr 25, 2018
Add answer
I have this question too (1)
Show all answers (1)

